233 research outputs found

    Outcomes of total hip arthroplasty, as a salvage procedure, following failed internal fixation of intracapsular fractures of the femoral neck: a systematic review and meta-analysis.

    Get PDF
    AIMS: The optimal management of intracapsular fractures of the femoral neck in independently mobile patients remains open to debate. Successful fixation obviates the limitations of arthroplasty for this group of patients. However, with fixation failure rates as high as 30%, the outcome of revision surgery to salvage total hip arthroplasty (THA) must be considered. We carried out a systematic review to compare the outcomes of salvage THA and primary THA for intracapsular fractures of the femoral neck. PATIENTS AND METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) compliant systematic review, using the PubMed, EMBASE and Cochrane libraries databases. A meta-analysis was performed where possible, and a narrative synthesis when a meta-analysis was not possible. RESULTS: Our analyses revealed a significantly increased risk of complications including deep infection, early dislocation and peri-prosthetic fracture with salvage THA when compared with primary THA for an intracapsular fracture of the femoral neck (overall risk ratio of 3.15). Functional outcomes assessment using EuroQoL (EQ)-5D were not significantly different (p = 0.3). CONCLUSION: Salvage THA carries a significantly higher risk of complications than primary THA for intracapsular fractured neck of femur. Current literature is still lacking well designed studies to provide a full answer to the question. TAKE HOME MESSAGE: Salvage THA is associated with more complications than primary THA for intracapsular neck of femur fractures

    Femoral bone mesoscale structural architecture prediction using musculoskeletal and finite element modelling

    Get PDF
    Through much of the anatomical and clinical literature bone is studied with a focus on its structural architecture, while it is rare for bone to be modelled using a structural mechanics as opposed to a continuum mechanics approach in the engineering literature. A novel mesoscale structural model of the femur is presented in which truss and shell elements are used to represent trabecular and cortical bone, respectively. Structural optimisation using a strain-based bone adaptation algorithm is incorporated within a musculoskeletal and finite element modelling framework to predict the structure of the femur subjected to two loading scenarios; a single load case corresponding to the frame of maximum hip joint contact force during walking and a full loading regime consisting of multiple load cases from five activities of daily living. The use of the full loading regime compared to the single load case has a profound influence on the predicted trabecular and cortical structure throughout the femur, with dramatic volume increases in the femoral shaft and the distal femur, and regional increases at the femoral neck and greater trochanter in the proximal femur. The mesoscale structural model subjected to the full loading regime shows agreement with the observed structural architecture of the femur while the structural approach has potential application in bone fracture prediction, prevention and treatment. The mesoscale structural approach achieves the synergistic goals of computational efficiency similar to a macroscale continuum approach and a resolution nearing that of a microscale continuum approach

    Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck

    Get PDF
    The present work introduces a method of screw fixation of femoral neck fractures in the presence of osteoporosis, according to an original concept of the establishment of two supporting points for the implants and their biplane positioning in the femoral neck and head. The provision of two steady supporting points for the implants and the highly increased (obtuse) angle at which they are positioned allow the body weight to be transferred successfully from the head fragment onto the diaphysis, thanks to the strength of the screws, with the patient’s bone quality being of least importance. The position of the screws allows them to slide under stress with a minimal risk of displacement. The method was developed in search of a solution for those patients for whom primary arthroplasty is contraindicated. The method has been analysed in relation to biomechanics and statics. For the first time, a new function is applied to a screw fixation—the implant is presented as a simple beam with an overhanging end

    Characterisation of the Immunophenotype of Dogs with Primary Immune-Mediated Haemolytic Anaemia

    Get PDF
    Immune-mediated haemolytic anaemia (IMHA) is reported to be the most common autoimmune disease of dogs, resulting in significant morbidity and mortality in affected animals. Haemolysis is caused by the action of autoantibodies, but the immunological changes that result in their production have not been elucidated.To investigate the frequency of regulatory T cells (Tregs) and other lymphocyte subsets and to measure serum concentrations of cytokines and peripheral blood mononuclear cell expression of cytokine genes in dogs with IMHA, healthy dogs and dogs with inflammatory diseases.19 dogs with primary IMHA, 22 dogs with inflammatory diseases and 32 healthy control dogs.Residual EDTA-anti-coagulated blood samples were stained with fluorophore-conjugated monoclonal antibodies and analysed by flow cytometry to identify Tregs and other lymphocyte subsets. Total RNA was also extracted from peripheral blood mononuclear cells to investigate cytokine gene expression, and concentrations of serum cytokines (interleukins 2, 6 10, CXCL-8 and tumour necrosis factor α) were measured using enhanced chemiluminescent assays. Principal component analysis was used to investigate latent variables that might explain variability in the entire dataset.There was no difference in the frequency or absolute numbers of Tregs among groups, nor in the proportions of other lymphocyte subsets. The concentrations of pro-inflammatory cytokines were greater in dogs with IMHA compared to healthy controls, but the concentration of IL-10 and the expression of cytokine genes did not differ between groups. Principal component analysis identified four components that explained the majority of the variability in the dataset, which seemed to correspond to different aspects of the immune response.The immunophenotype of dogs with IMHA differed from that of dogs with inflammatory diseases and from healthy control dogs; some of these changes could suggest abnormalities in peripheral tolerance that permit development of autoimmune disease. The frequency of Tregs did not differ between groups, suggesting that deficiency in the number of these cells is not responsible for development of IMHA

    A new measurement for posterior tilt predicts reoperation in undisplaced femoral neck fractures: 113 consecutive patients treated by internal fixation and followed for 1 year

    Get PDF
    Background and purpose Preoperative posterior tilt in undisplaced (Garden I–II) femoral neck fractures is thought to influence rates of reoperation. However, an exact method for its measurement has not yet been presented. We designed a new measurement for posterior tilt on preoperative lateral radiographs and investigated its association with later reoperation

    Alumina-on-alumina total hip replacement for femoral neck fracture in healthy patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Total hip replacement is considered the best option for treatment of displaced intracapsular fractures of the femoral neck (FFN). The size of the femoral head is an important factor that influences the outcome of a total hip arthroplasty (THA): implants with a 28 mm femoral head are more prone to dislocate than implants with a 32 mm head. Obviously, a large head coupled to a polyethylene inlay can lead to more wear, osteolysis and failure of the implant. Ceramic induces less friction and minimal wear even with larger heads.</p> <p>Methods</p> <p>A total of 35 THAs were performed for displaced intracapsular FFN, using a 32 mm alumina-alumina coupling.</p> <p>Results</p> <p>At a mean follow-up of 80 months, 33 have been clinically and radiologically reviewed. None of the implants needed revision for any reason, none of the cups were considered to have failed, no dislocations nor breakage of the ceramic components were recorded. One anatomic cementless stem was radiologically loose.</p> <p>Conclusions</p> <p>On the basis of our experience, we suggest that ceramic-on-ceramic coupling offers minimal friction and wear even with large heads.</p

    The web-based ASSO-food frequency questionnaire for adolescents: relative and absolute reproducibility assessment

    Get PDF
    Background: A new food frequency questionnaire (FFQ) has been recently developed within the Italian Adolescents and Surveillance System for the Obesity prevention (ASSO) Project; it was found to be appropriate for ranking adolescents in food and nutrient levels of intake. The aim of this study was to assess the relative and absolute reproducibility of the ASSO-FFQ for 24 food groups, energy and 52 nutrients. Methods: A test-retest study was performed on two ASSO-FFQs administered one month apart of each other to 185 adolescents, aged 14–17 and attending secondary schools in Palermo (Italy). Wilcoxon test assessed differences in median daily intakes between the two FFQs. Agreement was evaluated by quintiles comparison and weighted kappa. Intraclass Correlation Coefficients (ICC) and Bland-Altman method assessed the relative and absolute reliability respectively. Results: Significant difference (p < 0.05) in median intakes was found only for bread substitutes, savoury food, water, soft drinks, carbohydrates and sugar. The subjects classified into the same or adjacent quintiles for food groups ranged from 62% (white bread) to 91% (soft drinks); for energy and nutrients from 64% (polyunsaturated fatty acids) to 90% (ethanol). Mean values of weighted kappa were 0.47 and 0.48, respectively for food groups and nutrients. Fair to good ICC values (>0.40) were assessed for thirteen food groups, energy and forty-three nutrients. Limits of Agreement were narrow for almost all food groups and all nutrients. Conclusions: The ASSO-FFQ is a reliable instrument for estimating food groups, energy and nutrients intake in adolescents

    Automating Genomic Data Mining via a Sequence-based Matrix Format and Associative Rule Set

    Get PDF
    There is an enormous amount of information encoded in each genome – enough to create living, responsive and adaptive organisms. Raw sequence data alone is not enough to understand function, mechanisms or interactions. Changes in a single base pair can lead to disease, such as sickle-cell anemia, while some large megabase deletions have no apparent phenotypic effect. Genomic features are varied in their data types and annotation of these features is spread across multiple databases. Herein, we develop a method to automate exploration of genomes by iteratively exploring sequence data for correlations and building upon them. First, to integrate and compare different annotation sources, a sequence matrix (SM) is developed to contain position-dependant information. Second, a classification tree is developed for matrix row types, specifying how each data type is to be treated with respect to other data types for analysis purposes. Third, correlative analyses are developed to analyze features of each matrix row in terms of the other rows, guided by the classification tree as to which analyses are appropriate. A prototype was developed and successful in detecting coinciding genomic features among genes, exons, repetitive elements and CpG islands
    • 

    corecore